A Therapeutic Wireless Capsule for Treatment of Gastrointestinal Haemorrhage by Balloon Tamponade Effect
Publication in refereed journal

替代計量分析
.

其它資訊
摘要Objective: Wireless capsule endoscope (WCE) is a revolutionary approach to diagnose small bowel pathologies. Currently available WCEs are mostly passive devices with image capturing function only, while on-going efforts have been placed on robotizing WCEs or to enhance them with therapeutic functions. In this paper, the authors present a novel inflatable WCE for haemostasis in the gastrointestinal (GI) tracts by balloon tamponade effect. Methods: The proposed wireless capsule consists of a balloon that can be inflated using the endothermic reaction of acid and base. When the balloon reached a precalculated pressure level, it is able to stop at a bleeding site in the bowel, and achieve haemostasis by tamponade effect. The prototype is 14 mm in diameter, with three sections of 13, 35, and 12 mm in length, respectively. The three sections are linked together with flexible joints and enclosed in a silicone balloon. The prototypes were tested in ex vivo porcine intestine models. Results: In the ten ex vivo trials conducted, the inflatable wireless capsule achieved average balloon pressure of 46.0 mmHg and withstood average maximum longitudinal pulling force at 1.46 N. An in vivo study was carried out as a proof-of-concept for treating bleeding in a porcine model. The proposed inflatable WCE succeeded in the animal test by controlling haemostasis within 5 min. No rebleeding was observed in the next 20 min. Conclusion: The results suggested that the inflatable capsule with a real-time bleeding detection algorithm can be implemented. Moreover, the proposed inflatable WCE prototype can achieve haemorrhage control in the lower GI. Significance: To our best knowledge, this is the first study that demonstrated the potential to treat GI haemorrhage by an inflatable WCE. The proposed capsule enables the development of a closed-loop system based on a body sensor network to provide early treatment of GI bleeding for p-medicine.
出版社接受日期07.07.2016
著者Billy HK Leung, Carmen CY Poon, Ruikai Zhang, Yali Zheng, Cecilia KW Chan, Philip WY Chiu, James YW Lau, Joseph JY Sung
期刊名稱IEEE Transactions on Biomedical Engineering
出版年份2017
月份5
卷號64
期次5
頁次1106 - 1114
國際標準期刊號0018-9294
電子國際標準期刊號1558-2531
語言美式英語
關鍵詞Body sensor network, ingestible medical device, mobile health, wireless capsule endoscope (WCE)

上次更新時間 2020-29-10 於 01:34