摘要Drug abusers may attempt to conceal their drug intake by interfering with the clinical specimens sent to the laboratory for toxicology screening. This report describes a 27-year-old drug abuser who repeatedly submitted urine samples with abnormally low creatinine concentrations in order to invalidate drug screening. Adulteration by addition of ammonia-containing cleanser was suspected and eventually admitted by the patient. This case illustrates common features of urine adulteration. Various strategies for the prevention and detection of adulteration are also discussed. © 2005 Hong Kong College of Psychiatrists.
著者Tai H.L., Chan M.H.M., Lee D.T.S., Ng K.F., Law E.L.K., Lam C.W.K.