Comparison of corneal biomechanics after microincision lenticule extraction and small incision lenticule extraction
Publication in refereed journal

替代計量分析
.

其它資訊
摘要To evaluate and compare the change in corneal biomechanical properties after microincision lenticule extraction (MILE) and small incision lenticule extraction (SMILE).
In this prospective study, 60 eyes received MILE surgery with 2 mm opening incision, while 64 eyes received SMILE procedure with 5 mm opening incision. Corneal hysteresis (CH), corneal resistance factor (CRF) and 37 other biomechanical waveform parameters were quantitatively assessed using ocular response analyser (ORA) preoperatively and up to 6 months postoperatively. All changes were calculated as the difference between preoperative and postoperative values (Δ).
Both CH and CRF values decreased significantly after MILE and SMILE (p<0.001). ΔCRF (o=0.028) and ΔCRF index (ΔCRF/preoperative CRF) (p=0.043) were statistically lower for all eyes at 1-week follow-up. ΔCH index (ΔCH/preoperative CH) was statistically lower at 1-week (p=0.043) and 1-month (p=0.015) follow-ups in MILE group when compared with SMILE group. In both MILE and SMILE group, ΔCH index and ΔCRF index were positively correlated with preoperative manifest refraction spherical equivalent, residual stromal thickness (RST) index (RST/preoperative central corneal thickness) and negatively correlated with lenticule thickness (p<0.05).
Both MILE and SMILE procedures significantly altered the biomechanical characteristics of cornea. Smaller opening incision was associated with less reduction in ORA parameters during early postoperative period.
OBJECTIVES
METHODS
RESULTS
CONCLUSIONS
著者Wu Z, Wang Y, Zhang J, Chan TCY, Ng ALK, Cheng GPM, Jhanji, V
期刊名稱The British journal of ophthalmology
出版年份2017
月份5
卷號101
期次5
出版社BMJ Publishing Group
頁次650 - 654
國際標準期刊號0007-1161
語言英式英語

上次更新時間 2021-01-03 於 02:17