摘要The subtropical climate of Hong Kong has resulted in a significant amount of energy use for comfort cooling in summer.The situation is getting even worse because of the widespread use of household air-conditioners in high-rise residential buildings in the last two decades. To improve the situation, it is believed that thermal comfort has to be made an important agenda in building design. This paper discusses the adaptive model in thermal comfort, which has been included in the new revision of ASHRAE Standard 55-2004. Furthermore, it demonstrates the development of a comfort temperature chart for naturally ventilated buildings in Hong Kong. Based on the findings of this study, indoor natural ventilation to airspeed of about 1.0 - 1.5 m/s would likely satisfy the thermal comfort requirements of 80% of occupants during the hot summer period in Hong Kong. © 2006 University of Sydney. All rights reserved.
著者Cheng V., Ng E.
期刊名稱Architectural Science Review
出版年份2006
月份6
日期1
卷號49
期次2
出版社University of Sydney
出版地Australia
頁次179 - 182
國際標準期刊號0003-8628
電子國際標準期刊號1758-9622
語言英式英語

上次更新時間 2020-25-06 於 01:14