Randomized comparison of closed-loop feedback computer-controlled with manual-controlled infusion of phenylephrine for maintaining arterial pressure during spinal anaesthesia for Caesarean delivery
Publication in refereed journal


Times Cited
Web of Science39WOS source URL (as at 19/11/2020) Click here for the latest count
Altmetrics Information
.

Other information
AbstractClosed-loop feedback computer-controlled infusion has not been described for administering phenylephrine to maintain arterial pressure (AP) during spinal anaesthesia for Caesarean delivery. We aimed to compare AP control using this automated system with a previously described manual infusion system.
All Author(s) ListNgan Kee WD, Khaw KS, Ng FF, Tam YH
Journal nameBritish Journal of Anaesthesia
Year2013
Month1
Day1
Volume Number110
Issue Number1
PublisherOxford University Press (OUP): Policy B - Oxford Open Option B
Pages59 - 65
ISSN0007-0912
eISSN1471-6771
LanguagesEnglish-United Kingdom
Keywordsanaesthesia, spinal; arterial pressure, hypotension; Caesarean delivery