摘要The inadequate reaction time of the peroneal muscles in response to an incorrect foot contact event has been proposed as one of the etiological factors contributing to ankle joint inversion injury. Thus, the current study aimed to investigate the efficacy of a myoelectric stimulation applied to the peroneal muscles in the prevention of a simulated ankle inversion trauma. Ten healthy male subjects performed simulated inversion and supination tests on a pair of mechanical sprain simulators. An electrical signal was delivered to the peroneal muscles of the subjects through a pair of electrode pads. The start of the stimulus was synchronized with the drop of the sprain simulator's platform. In order to determine the maximum delay time which the stimulus could still resist the simulated ankle sprain motion, different delay time were test (0, 5, 10, and 15 ms). Together with the control trial (no stimulus), there were 5 testing conditions for both simulated inversion and supination test.
著者Fong DTP, Chu VWS, Chan KM
期刊名稱Journal of Biomechanics
出版年份2012
月份7
日期26
卷號45
期次11
出版社Elsevier
頁次2055 - 2057
國際標準期刊號0021-9290
電子國際標準期刊號1873-2380
語言英式英語
關鍵詞Ankle ligamentous sprain; Biomechanics; Injury prevention
Web of Science 學科類別Biophysics; BIOPHYSICS; Engineering; Engineering, Biomedical; ENGINEERING, BIOMEDICAL

上次更新時間 2020-18-10 於 00:42